The status indicator LED on my Align 3G unit changes from red to green at mid-stick cyclic. This reverses the direction of the servo plugged in to the pitch port of the sensor at mid stick, so it goes from negative, up to the neutral point, and back down to negative.
Pitch curve is linear, zero to 100.
The heli has flown recently, I am not sure if this is something in thae radio or with the sensor unit. Has anyone had a similar experience, or know what may be causing this?
Mechanically all looks fine so I am guessing it is something in the setup of either the radio or the 3g unit.

PM  EMAIL  GALLERY  Attn:RR  Quote
04-26-2011 06:50 PM  7 years agoPost 2
willanyone1

rrApprentice

Griffith, IN U.S.

My Posts: All  Forum  Topic

i would say the unit, try reprograming it. and that should fix her.

PM  EMAIL  GALLERY  Attn:RR  Quote
04-26-2011 10:01 PM  7 years agoPost 3
jsenicka

rrProfessor

Eagle River, WI

My Posts: All  Forum  Topic

you either have the plugs to receiver wrong, radio CCPM setup wrong (should be ccpm-120) or servos pluged in wrong, or need to rerun DIR setup. It can't be anything else

On JR receiver, verify aileron to aileron, elevator to elevator and pitch to Aux1.
On servo side, center servo goes to elevator, left goes to pitch, right to aileron.

Jim Senicka
Team Manager, GrandRC Flight Team

PM  EMAIL  GALLERY  Attn:RR  Quote