03-04-2008 11:14 PM  10 years agoPost 1
lightningrc

rrElite Veteran

UK

My Posts: All  Forum  Topic

Could not work out y my TP210 balancer alarm would not go off showing 6 led's and constant bleeping .

I tested the balance plug voltages and all seemed fine until I got to the last yellow and red which one was reading aprox. 24 and the other 11 which I thought was strange.

I tested my other 5000 extreme and these last 2 wires should have no voltage , so I carefully pulled on the red and yellow wires and could not believe there just tucked in under the heatshink where they where rubbing against the contacts on the top of the lipos .

I now removed both the red and yellow wire on both lipos from the balance plugs for this problem never to happen again.
Both batteries now balance and charge perfect

Surely these spare wires should be removed when being built in the factory and not just left in there.

PM  EMAIL  HOMEPAGE  GALLERY  Attn:RR  Quote
03-05-2008 09:49 AM  10 years agoPost 2
fergus

rrKey Veteran

Ireland

My Posts: All  Forum  Topic

I would be sending a snorter to Thunderpower - that is ridiculous that these wires were at least not insulated at the loose end if not even removed.

Regards

Fergus

Regards

Fergus

PM  EMAIL  GALLERY  Attn:RR  Quote
WATCH
 1 page 397 views POST REPLY
HomeAircraftHelicopter
e-
Electric Battery-Charger-pSupply
› TP 5000 Extreme balance plug fault (Remove the red & yellow)
 Print TOPIC  Make Suggestion 

 1  Topic Subscribe

Monday, June 25 - 12:48 pm - Copyright © 2000-2018 RunRyder   EMAILEnable Cookies

Login Here
 New Subscriptions 
 Buddies Online