RunRyder RC
WATCH
 1 page 424 views POST REPLY
02-08-2008 08:11 PM  11 years ago
Topic Vote0Post 1
holzback

rrKey Veteran

noblesville IN United States

MyPosts All Forum Topic
balencing
i use a 1010 charger and a 210 balencer. when i plug in a tp 6s 5000 mah battery to the balencer the red lights blink meaning that there is a imbalence. when my 1010 charger reads the balencer it says a .01-.015 imbalence. according to the 210 directions there should be no blinking of the lights,unless the imbalence is over .03. dose anyone else have this confertation?

thanks josh
SHARE  PM  EMAIL  GALLERY  Attn:RR  Quote
02-11-2008 03:45 AM  11 years ago
stanc

rrKey Veteran

Conroe, TX

MyPosts All Forum Topic
What is the voltage of the pack when this is happening? If the voltage
of the pack is less than what the balancer thinks it should be the lights will blink. Start the charger and let it build up the voltage, then press and hold the SEL/MOD button, the balance values will come up and you can see if the cells are coming into balance.

Stan
Stan
2- Logo 500
Ion X2
eAvro90
SHARE  PM  EMAIL  GALLERY  Attn:RR  Quote
02-11-2008 05:05 AM  11 years ago
holzback

rrKey Veteran

noblesville IN United States

MyPosts All Forum Topic
the pack voltage is fine,it is far from being to low. the imbalence reads .01 on the 1010 and the balencer will still have lights on balencing,even if i reset it. i just wanted to know if anyone else has this issue, it is not really a problem.
SHARE  PM  EMAIL  GALLERY  Attn:RR  Quote
02-11-2008 06:41 AM  11 years ago
Blik

rrApprentice

Ontario North

MyPosts All Forum Topic
Your balancer is working correctly.
when my 1010 charger reads the balencer it says a .01-.015 imbalence. according to the 210 directions there should be no blinking of the lights,unless the imbalence is over .03. dose anyone else have this confertation?
Your pack is not balanced if the 1010C is showing .01-.015 imbalance and that is why the 210 is working away.

Here are the correct specs for the TP balancers:

Auto balance active if more than 0.005V imbalance)
Over voltage safety alerts (also shut-off TP charger if detected any 4.3V cell during charging)

Cheers
Blik
SHARE  PM  EMAIL  GALLERY  Attn:RR  Quote
02-12-2008 03:45 PM  11 years ago
holzback

rrKey Veteran

noblesville IN United States

MyPosts All Forum Topic
ok thanks
SHARE  PM  EMAIL  GALLERY  Attn:RR  Quote
WATCH
 1 page 424 views POST REPLY
 Print TOPIC  Make Suggestion 