RunRyder RC
 3  Topic Subscribe
WATCH
 1 page 1224 views POST REPLY
Helicopter
e-
Synergy R/C
Synergy E6 › Scorpion motor E6
01-25-2012 06:29 PM  6 years agoPost 1
Ejeremy

rrKey Veteran

Bourbonnais,IL

My Posts: All  Forum  Topic

Anyone running a scorpion motor in there E6 on 12s?
Thanks Jeremy

Team Futaba
Team Thunder Tiger
Team Radix
VP Powermaster Fuels

PM  EMAIL  GALLERY  Attn:RR  Quote
01-29-2012 11:44 PM  6 years agoPost 2
Ejeremy

rrKey Veteran

Bourbonnais,IL

My Posts: All  Forum  Topic

Ok what motor is everyone running in the E6 on 12s?

Thanks guys Jeremy

Team Futaba
Team Thunder Tiger
Team Radix
VP Powermaster Fuels

PM  EMAIL  GALLERY  Attn:RR  Quote
01-29-2012 11:47 PM  6 years agoPost 3
4cyclic

rrKey Veteran

Montreal, Can. and northern Vermont

My Posts: All  Forum  Topic

Running Hacker 470kv on 12s in my E6. 120 flights so far. Good motor for sure.

Life is meaningful flying helis.

PM  EMAIL  GALLERY  Attn:RR  Quote
01-29-2012 11:59 PM  6 years agoPost 4
Steff Giguere

rrProfessor

St-Eustache, Quebec, Canada

My Posts: All  Forum  Topic

On the E6 I would run the 4035-500kv Scorpion motor.
Myself I'm running the Hacker 470kv.

Team Synergy, Rail blades, Team Scorpion, V-Team

PM  EMAIL  HOMEPAGE  GALLERY  Attn:RR  Quote
01-30-2012 12:08 AM  6 years agoPost 5
Darren Lee

rrElite Veteran

Woodstock, GA

My Posts: All  Forum  Topic

Hacker Turnado 470kv

Team Synergy / Rail Blades / Morgan Fuel

PM  EMAIL  GALLERY  Attn:RR  Quote
01-30-2012 01:15 AM  6 years agoPost 6
Ejeremy

rrKey Veteran

Bourbonnais,IL

My Posts: All  Forum  Topic

Thanks guys

Team Futaba
Team Thunder Tiger
Team Radix
VP Powermaster Fuels

PM  EMAIL  GALLERY  Attn:RR  Quote
01-30-2012 01:26 AM  6 years agoPost 7
ben_beyer

rrApprentice

Canyon, TX

My Posts: All  Forum  Topic

What about for a 10S set up?

PM  EMAIL  GALLERY  Attn:RR  Quote
01-30-2012 01:54 AM  6 years agoPost 8
Darren Lee

rrElite Veteran

Woodstock, GA

My Posts: All  Forum  Topic

Hacker Turnado 580kv

Team Synergy / Rail Blades / Morgan Fuel

PM  EMAIL  GALLERY  Attn:RR  Quote
01-30-2012 01:56 PM  6 years agoPost 9
ben_beyer

rrApprentice

Canyon, TX

My Posts: All  Forum  Topic

What about a HK 4025-550?

It's a little lighter than the Hacker but a little slower (I.E. 580 vs. 550 KV).

PM  EMAIL  GALLERY  Attn:RR  Quote
01-30-2012 02:10 PM  6 years agoPost 10
Darren Lee

rrElite Veteran

Woodstock, GA

My Posts: All  Forum  Topic

What about a HK 4025-550?
That motor will not work because it has a 5mm shaft and 25mm bolt spacing. You need a 6mm shaft and 30mm spacing.

The best choice for a 10S Scorpion is the HKIII 4035-560.

Team Synergy / Rail Blades / Morgan Fuel

PM  EMAIL  GALLERY  Attn:RR  Quote